DESOZONE Specs for Municipal and Industrial Customers

DESOZONE Skid Mounted System

To download a PDF Version of this Data in English Units Click Here

Process Description

Air containing odors to be removed is drawn from an area or a process and washed with basic ozonated water recycled by the pump. Sodium hydroxide is added to the recirculated water by a dosing pump equipped with a pH controller.

DESOZONE System Components

Ozone generator
Air compressor with pre-filter and cooler (customer supplied)
Air filter
Air drier
Cooling water and drain (customer supplied)
Ozone mixing device
Ozone destroyer
Washing system
Contact chamber with packing
Sodium hydroxide addition pump
Sodium hydroxide storage tank
pH control
Blower
Recycle pump

Air to Treat (m3/h)2505001,0002,500
Air to Treat (SCFM)1563136251563
O3 Required (g/h)24820
O3 Generator Power (KW)0.030.060.120.25
Total Power (KW)0.91.22.83.6
Compressed Air (m3/h)0.5125
Blower power (KW)0.50.751.52.2
Recycle Pump Flow (m3/h)1125
Recycle Pump Power(KW)0.30.31.11.1
Coolant Water flow (l/h)5102040
Dried Air (m3/h)0.10.10.51.0
Dimensions W x L x H (m)1.4 x 2.1 x 2.21.4 x 2.1 x 2.21.6 x 2.1 x 2.21.6 x 2.1 x 2.2
Air to Treat (m3/h)5,00010,00015,00020,000
Air to Treat (SCFM)3,1256,2509,37512,480
O3 Required (g/h)4080120160
O3 Generator Power (KW)0.61.21.82.4
Total Power (KW)5.58.312.215.7
Compressed Air (m3/h)5101520
Blower power (KW)2.23.35.57.3
Recycle Pump Flow (m3/h)10203040
Recycle Pump Power(KW)2.23.34.45.5
Coolant Water flow (l/h)80160240320
Dried Air (m3/h)2468
Dimensions W x L x H (m)2 x 5.5 x 2.22 x 5.5 x 2.22.3 x 5.5 x 2.22.3 x 5.5 x 2.2

Specifications

Ozone Generator

Dosage8 mg/m3 of air
Design temperature 30 degrees C
Operating frequency820 Hz
Operating voltage, max3-9 kV

Cooling water

Temperature in/out 15/20 degrees C
Operating pressure 1 bar

Compressor ( EXCLUDED FROM OUR SUPPLY)

TypeOil Free

Air Filters

Coalescent and Carbon

Electrical

380 V, 3 Phase, 60 Hz.

Air Drier

Typemicroporous
Design pressure10 bar
Actual Pressure7 bar
Design temperature30 degrees C
Dew point (at 1 bar)-60 degrees C

Sodium Hydroxide

NaOH concentration40%
Dosing pump capacity0.2 to 2 L/hr Type 200 to 2500 0.4 to 4 L/hr Type 5000 to 20000
Storage tank50 L Type 200 to 2500 100 L Type 5000 to 20000

Ozone Mixer and Residual Ozone Destroyer

Power required100 W Type 200 to 2500 500 W Type 5000 to 20000

Scrubber

TypeHorizontal
Material PP
PackingPall/Raschig
Head loss100 mm.w.c.
WxLxH 0.5 x 1.4 x 1.6 to 0.8 x 1.6 x 1.6m Type 200 to 2500
WxLxH1.3 x 4.5 x 2.2 to 1.7 x 4.5 x 2.2m Type 5000 to 20000

Complete with internal drop separator, service piping, valves, bottom tank, drainage, man-hole, level switches.

Blower

Head170 mm.w.c.
MaterialPP
RPM2850
Noise85 dB at 2 m
ProtectionIP 55
Transmission Direct

Recycle Pump

Head 10 m.w.c.
Material PP
ProtectionIP 55
RPM2900

Complete with valves, filter and service piping, manometer.

Ambient Conditions

Pressure1000 m bar